-40%
USA! 1PC-12VDC 30 AMP RELAY PLC CYCLE TIMER, MULTIFUNCTION DELAY MODULE !
$ 8.71
- Description
- Size Guide
Description
1 PCS OF A 12VDC PLC MULTIFUNCTION PROGRAMMABLE 30 AMP RELAY BOARD ,THESE WORK EXACTLY LIKE THE REGULAR 12 VDC 10 AMP BOARD ,
JUST A HEAVY DUTY RELAY !
18 MODES AND SOME ARE A TRIGGER
AND SOME ARE NOT , VERY NICE !!
Module Functions
Tips: Function 1-8 on power-up self-start function 9-18 require high pulse signal (high duration is shorter than 20ms, hereinafter the same) trigger the start.
Function 1:
Timing Pick: After power, time delay relay pull T1, T1 between 0.1 seconds -270 hours adjustable, IN interface to a
high
level pulse signal, repeat the above functions;
Function 2:
Timing off: when the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, IN interface to a
high
level pulse signal, repeat the above functions;
Function 3:
Timing pull off again: After power relay to not pull, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 in 0.1 seconds -270 hours between adjustable, CH1 interface to a
high
pulse signal, repeat the above functions;
Function 4:
Timing and then pull off: After power, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, -270 hour in 0.1 seconds delay time between T1 and T2 adjustable to CH1 interface a
high
pulse signal, repeat the above functions;
Function 5:
Infinite loop timing mode 1: After power relay to not pull, after the delay time T1 reaches the relay is energized; pull the relay off after time T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 adjustable between second -270 hours, giving a
high
level pulse signal CH1 interface, you can restart the above functions;
Function 6:
Infinite loop timing mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting time T2 relay, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, giving a
high
level pulse signal CH1 interface, you can restart the above functions;
Function 7:
Finite loop timing mode 1: 5 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a
high
pulse signal, the above functions can be re-started;
Function 8:
Finite loop timing mode 2: 6, on the basis of the function, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a
high
pulse signal, the above functions can be re-started;
Function 9:
Latching relay modes: CH1 interface to relay a
high
level pulse signal, relay, give a
high
pulse signal relay disconnected.
Function 10:
Trigger relay modes: CH1 interface to a
high
signal relay, relay,
low
disappear, relay disconnected.
Function 11:
Pull the trigger timing: After power relay does not act, a
high
-level interface to CH1 pulse signal, the delay time relay pull T1, T1 between 0.1 seconds -270 hours adjustable, repeating a
high
level interface to CH1 pulse signal, repeat the above function;
Function 12:
Trigger timing off: After power relay does not act, a
high
-level interface to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 interface a
high
pulse signal, repeat the above functions;
Function 13:
Pull the trigger timing then disconnect: After power relay does not act, CH1 interface to a
high
level pulse signal, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 between 0.1 seconds -270 hours adjustable, repeat CH1 interface to a
high
level pulse signal, repeat the above functions;
Function 14:
Disconnect and then pull the trigger timing: After power relay does not act, a
high
-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a
high
level pulse signal, repeat the above functions;
Function 15:
Infinite loop timing mode 1: After power relay does not operate to a
high
level pulse signal CH1 interface, the delay time T1 reaches the relay is energized; pull off the relay arrival time T2, and then repeat the above condition, the extension when the time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a
high
level pulse signal, the above functions can be re-started;
Function 16:
Infinite loop timing mode 2: After power relay does not act, a
high
-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; break time T2 after reaching relay, then repeat the above condition, the delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a
high
level pulse signal, the above functions can be re-started;
Function 17:
Finite loop timing mode 1: 15 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a
high
pulse signal, the above functions can be re-started;
Function 18:
Finite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a
high
pulse signal, the above functions can be re-started;
Connections:
Module Voltage Signal Input:There have three interfaces, all interfaces have terminal,user easy to use.
1.GND : DC 12V Negative
2.12V : DC 12V Positive
3.IN1:Input signal interface. (2.5-24V high voltage to be valid; 0-0.6V low voltage to be invalid;0.7V-2.4V voltage is unpredictable,you should avoid this voltage range)
A VERY IMPRESSIVE PRODUCT , I WILL BE ADDING TO THE DETAILS VERY SOON , MANY MANY FEATURES , NOTICE THE MANUAL LISTS SOME OF THE FEATURES , STILL A LOT OF GOOD FUNCTIONS , WITH AND WITHOUT , HIGH SIGNAL NEEDED . HAS SOME FUNCTIONS THAT ARE CYCLE RELAY ON FOR ADJUSTABLE TIME , THEN OFF FOR ADJUSTABLE TIME , THEN REPEATS , OR CAN SET TO RECEIVE ANOTHER HIGH PULSE BEFORE REPEATING SET TIMES , NICE ! ** , I HAVE NOT FINISHED THE NEW MANUAL THAT IS CORRECT , PLEASE ASK IF WHAT YOU WOULD NEED IT TO DO , IS POSSIBLE . I WILL SET ONE UP FOR YOUR RECOMMENDATION TO ENSURE THE FEATURE WILL WORK !! , SHIPS OUT SAME DAY OR WITHIN 24 HOURS OF CLEARED PAYMENT NEXT WORKING DAY , USPS MAIL !!
SETTING INSTRUCTIONS ; THESE ARE VERY MUCH LIKE SETTING AN OLD DIGITAL WATCH , JUST PRESS THE SET BUTTON UNTIL THE DISPLAY FLASHES , IT STARTS WITH THE LED BLINKING BESIDE THE "MD"= MODE , USE THE NUM- & NUM+ BUTTONS TO ADJUST IT UP OR DOWN , ALSO THE "SWI" BUTTON WILL CHANGE THE DISPLAY SETTING TO THE NEXT DIGIT , AFTER SETTING THE MODE , PRESS THE SET BUTTON AGAIN THIS STORES THE MODE AND INCREMENTS THE DISPLAY TO SET THE "T1"= TIMER 1 , IT TOO ADJUSTS WITH THE NUM- & NUM+ BUTTONS AND THE "SWI" BUTTON, CHANGES THE DIGITS TO BE ADJUSTED , WHEN FINISHED PRESS THE SET BUTTON AGAIN , IT SAVES AND INCREMENTS TO THE "T2"= TIMER 2 , REPEAT THE SAME FOR THIS ALSO AND WHEN FINISHED PRESS "SET" , IT WILL THEN INCREMENT TO THE "NX"= INTERNAL CLOCK , THIS FEATURE WILL CHANGE THE TIMING METHOD AND SHOULD BE LEFT ALONE ( THE DEFAULT FOR SECONDS IS 101 ) PRESS AND HOLD SET AGAIN , ALL FINISHED !! , THE BOARD WILL START THE SETTINGS YOU HAVE SET , SOME MODES REQUIRE A +12VDC INPUT TO RESTART , AND SOME MODES DO NOT .
Package:
1 PC OF A 12 VDC PLC WITH 30 AMP RELAY 4 KEY 1-9999 SECONDS PROGRAMMABLE TIMER RELAY