-40%
DC 5V 12V 24V Multifunction Delay Time On/Off Timing Cycle Timer Relay Switch
$ 3.45
- Description
- Size Guide
Description
Store HomeCapacity Meter
Relay Module
Power Converter
Gear Motor
BMS Board
Digital Meter
Speed Control
DC Motor
Store category
SPI OLED LCD Display Module
Step up down module
Motor Pump Speed control
Mini high speed motor
Relay Module
Micro coreless motor
Temperature Control Switch
Stepper motor
High power speed motor
Car Cigarette Lighter Socket
Audio Power Amplifier Board
Battery Protection Board
Mini air water pump
DC Solenoid Electromagnet
Digital Voltmeter Ammeter
Reduction Gear Motor
Vibrator Vibration Motor
18650 Battery Protection Board
DIY Phone charger
AC-DC Power Supply Module
Battery Capacity Meter
Battery Charger Adapter
DIY Quadcopter Drone Parts
DIY Toy Hobby Parts
battery charger module
Sign Up Now !
You may also like
DC 5V 12V 24V Multifunction Delay Time On/Off Timing Cycle Timer Relay Switch
Product Description
Features:
DC 5V/12V/24V available, can select version you need and buy.
This multifunction relay control module, designed specifically for a variety of users with
different needs, preset 18 kinds of
functions, and can set based on user needs, customize and add specific functions.
The product was isolated power supply industrial power modules, it has a temperature
protection, over current protection
and short circuit full protection, high and low voltage
isolation. work is very stable.
input with optocoupler isolation, enhanced anti-jamming capability, to ensure
stability.
(1) the module 18 kinds function, to meet the needs of more applications,
(2) Increase the supply anti—reverse function, and does not take the wrong power supply is
damaged module,
(3) The use of top-quality. high—voltage power supply modules, discrete power supply before
replacing the system more stable and reliable,
(4) There are 0. 1 seconds / 1 second / l in three timing, timing accuracy of 0. 01 seconds,
(5) Increase automatic power saving feature, users can independently set.
Module Function:
Function 1—8 start at power on,
Function 9—18
is triggered(can add button directly on the trigger terminal, or external trigger source) to start.
delay time T1 and T2 in
0.1second —270 hour Adjustable
Notes: If you use external (high level, more than 20mS) trigger source, should use same GND to the module GND.
Function 1:
Timing relay pull(delay turn on): Power-up. delay T1 time, then relay pull(switch connect),
trigger it, repeat the above functions.
Function 2:
Timing relay off(delay turn off): power-up , relay pull(switch connect), delay T1 time, then relay off,
trigger it, repeat the above functions.
Function 3:
Timing relay pull then off: Power-up, relay states off, delay T1 time relay pull(connect), delay T2 time,
relay off,
trigger it, repeat the above functions.
Function 4:
Timing relay off then pull: After power, relay pull
immediately
, Relay off after delay time
T1, relay pull after T2 time,
trigger it, repeat the above functions.
Function 5:
Infinite loop delay time off/on: After power, relay not connect, the delay time T1 then relay connect
, Delay T2 time then relay disconnect,
and then cycle this working mode.
trigger it, will restart the above functions.
Function 6:
Infinite loop delay time off/on: After power, relay connect, the delay time T1 then relay disconnect
, Delay T2 time then relay connect,
and then cycle this working mode.
trigger it, will restart the above functions.
Function 7:
Finite loop timing mode: Based on the function 5, increasing the number of cycles ,
NX cycles adjustable
between 1—9999 times.
Function 8:
Finite loop timing mode: Based on the function 6, increasing the number of cycles ,
NX cycles adjustable
between 1—9999 times.
Function 9:
Latching relay modes: trigger, the relay pull, trigger
again relay disconnected.
Function 10:
Trigger relay modes: with trigger relay pull
, without trigger, relay disconnected.
Function 11:
Trigger timing pull: After power relay does not act.
Trigger it. delay T1 time, then relay pull(switch connect),
trigger it again, repeat the above functions.
Function 12:
Trigger timing off After power relay does not act.
Trigger it, relay pull(switch connect), delay T1 time, then relay off,
trigger it again, repeat the above functions.
Function 13:
Trigger timing pull and then disconnect: After power relay does not act.
Add trigger start, other working mode is same to Function 3.
Function 14:
Trigger timing disconnect and then pull : After power relay does not act.
Add trigger start, other working mode is same to Function 4.
Function 15:
lnfinite loop timing mode1:
After power relay does not act.
Add trigger start, other working mode is same to Function 5.
Function 16:
Infinite Loop Timing Mode 2:
After power relay does not act.
Add trigger start, other working mode is same to Function 6.
Function 17:
Finite loop timing mode 1:
After power relay does not act.
Add trigger start, other working mode is same to Function 7.
Function 18:
Finite loop timing mode 2:
After power relay does not act.
Add trigger start, other working mode is same to Function 8.
Working and Setting.
Connect to Power - Module work and display countdown.
Set the time range:
in working condition, long press
UP
key,
Display T1-X (--01/02/03/04/05), set T1 time range, press
UP
key X scroll, click
SET
key to confirm.
Then display T2-X
(--01/02/03/04/05), set T2 time range, press
UP
key X scroll,
press the
Enter
key to
save.
--01:0.01 second (0.01—99. 99 seconds)
--02:0.1 second (0.1—999.9 seconds)
--03:1 second (1—9999 seconds)
--04:1 minute (1—9999 minutes)
--05:1 hour (1—9999 hours)
Select function:
(1) long press
SET
to enter the function selection, display P—0X,
(X: 1-18) click the
SET
button to select the corresponding function and press
Enter
to confirm.
(2) Press
UP
/
DOWN
to add and subtract T1 time, press
Enter
to confirm.
(3) Press
UP
/
DOWN
to add and subtract T2 time, press
Enter
to confirm.
(4) Press the
UP
/
DOWN
to add and subtract NX times, press
Enter
to confirm. setup is
complete, the control panel start working.
Power Save Settings:
In the process of running the state, long press the Enter key to
closing and opening the digital display.
Interface:
Relay outputs: 3—wire interface, all interfaces are terminals
1, CK: normally open relay interface, the relay pull before the vacant , relay pull after
short with COM
2, COM: Common interface Relays
3, CB: normally closed relay interface COM relay shorted before and after the pull—vacant
Load capacity: normally open port maximum load capacity: DC 0—30v/l0A, AC 0—2500v/l0A
NC port maximum load capacity: DC 0—28v/l0A, AC 0—l25v/l0A
Payment
Delivery details
Terms of sales
Return
Contact us
Payment
We only accept payment via Paypal.
The buyer is responsible for any applicable import duties and local taxes.
Usually there's no any charges for small parcel. But please verify with your customs before making your purchase.
Delivery details
The items will be shipped within 1~2 working days after your payment is received and cleared.(excluding Saturday, Sunday & Holiday)
All items will be shipped to your Paypal address, so please make sure to provide us with the correct, precise, detailed shipping address.
The Delivered time to USA buyer is about 7~20 days, other country about
15~35
days delivered.
Notes: pls contact us if you need need trackable or express shipping service.
Terms of sales
All the items will be tested before shipping. Buy them with the confidence!
We maintain the excellent service standards
and strive for 100% customer satisfaction and
Positive feedback.
If you have any problem, please do feel free to contact us before leave Neutral
or Negative
feedback, so that we can satisfactorily address your concerns.
Return
We afford all cost if it's our fault. Exchange or refund.
Contact us
We strive to provide you with the best service, reply your question within 24 hours.
Business time:
9:30~21:30 (GMT+8)
exclude the weekend and holidays.
Contact us
Payment
Shipping
Return policy
About us